
LUGB Vortex Flow Meter
LUGB Vortex Flow Meter
LUGB flanged vortex flow meter for gas, liquid and steam measurement, DN15 to DN300 (flange sizes to DN350).
Specifications
- Series
- LUGB vortex flow meter
- Medium
- Gas, liquid, steam
- Nominal Sizes
- Flange DN15 to DN300 (shown to DN350); clamp DN15 to DN200; sanitary clamp DN25 to DN100
- Accuracy
- Liquid class 1; gas class 1.5
- Medium Temperature
- Standard -25 to +80 °C; high temp -25 to +250 °C or -25 to +300 °C
- Ambient Temperature
- -25 to +55 °C
- Pressure Rating
- 1.6 MPa / 2.5 MPa / 4.0 MPa
- Body Material
- Stainless steel 304; converter housing aluminium alloy
- Output
- Pulse and 4-20 mA; RS485 available
- Power Supply
- DC12 V ±10%, DC24 V ±10%, 3.6 V lithium battery
- Protection
- IP65
- Liquid Flow Range DN15
- 0.3–3 m³/h
- Liquid Flow Range DN20
- 0.5–5 m³/h
- Liquid Flow Range DN25
- 1.2–12 m³/h
- Liquid Flow Range DN32
- 1.5–15 m³/h
- Liquid Flow Range DN40
- 2.2–22 m³/h
- Liquid Flow Range DN50
- 4–40 m³/h
- Liquid Flow Range DN65
- 6–60 m³/h
- Liquid Flow Range DN80
- 9–90 m³/h
- Liquid Flow Range DN100
- 14–140 m³/h
- Liquid Flow Range DN125
- 22–220 m³/h
- Liquid Flow Range DN150
- 35–350 m³/h
- Liquid Flow Range DN200
- 65–650 m³/h
- Liquid Flow Range DN250
- 120–1200 m³/h
- Liquid Flow Range DN300
- 180–1800 m³/h
- Gas Flow Range (working) DN15
- 5–30 m³/h
- Gas Flow Range (working) DN20
- 5.5–56 m³/h
- Gas Flow Range (working) DN25
- 10.2–80 m³/h
- Gas Flow Range (working) DN32
- 15–150 m³/h
- Gas Flow Range (working) DN40
- 22–220 m³/h
- Gas Flow Range (working) DN50
- 35–350 m³/h
- Gas Flow Range (working) DN65
- 60–600 m³/h
- Gas Flow Range (working) DN80
- 90–900 m³/h
- Gas Flow Range (working) DN100
- 140–1400 m³/h
- Gas Flow Range (working) DN125
- 220–2200 m³/h
- Gas Flow Range (working) DN150
- 300–3000 m³/h
- Gas Flow Range (working) DN200
- 550–5500 m³/h
- Gas Flow Range (working) DN250
- 1100–11000 m³/h
- Gas Flow Range (working) DN300
- 1500–15000 m³/h
- Saturated Steam Capacity
- Pressure-specific: 0.1–4.3 MPa table, DN25–200 (kg/h); state line pressure for the exact range
Where the LUGB Vortex Flow Meter Fits
The LUGB vortex flow meter measures gas, liquid and steam in industrial pipelines. The catalog describes low pressure loss, a wide range, high accuracy, and a measurement of working-condition volume flow that is essentially unaffected by fluid density, pressure, temperature or viscosity.
Because there are no moving mechanical parts, the catalog describes high reliability and low maintenance.
Construction and Specifications
Flanged sizes run from DN15 to DN300, with DN350 shown in the flange size table. Clamp connection covers DN15 to DN200 and sanitary clamp covers DN25 to DN100. Accuracy is class 1 for liquid and class 1.5 for gas.
Medium temperature versions cover standard duty from -25 to +80 °C, and high temperature from -25 to +250 °C or -25 to +300 °C. Pressure ratings are 1.6 MPa, 2.5 MPa or 4.0 MPa. The body is stainless steel 304 and the converter housing is aluminium alloy, with IP65 protection.
Output can be pulse or 4-20 mA, with RS485 available. Power supply is DC12 V, DC24 V or a 3.6 V battery.
Ordering Guidance
Provide the medium (gas, liquid or steam), pipe size, flow range, pressure and temperature, and the output you need. Where steam or gas properties change with pressure and temperature, ask about the temperature and pressure compensation version.
What to Include in Your Inquiry
When requesting a quotation for an LUGB vortex flow meter, please provide: the medium (liquid, gas or steam); for steam, whether it is saturated or superheated and the line pressure; pipe DN; minimum, normal and maximum flow; operating pressure and temperature; the compensation option (A none, B temperature, C pressure, D integrated temperature-pressure, E separate temperature-pressure); output and power supply; pipe orientation; and the available straight-run lengths.
